To specify a glow discharge cleaning system to be used in the conditioning of the ETE tokamak vacuum vessel, a simple system was constructed and tested in a small chamber. This system works with a DC source (300 or 600 V) together with a high voltage pulse generator to trigger the discharge. The discharge tests were performed with argon, nitrogen and helium at several pressures.